Back to top
Cuvette For Spectophotometer And Florimeter
Cuvette For Spectophotometer And Florimeter

Cuvette For Spectophotometer And Florimeter

Price 400 INR/ Pair

MOQ : 1 Pair

Cuvette For Spectophotometer And Florimeter Specification

  • Resolution
  • Depends on spectrophotometer; cuvette contributes negligible error
  • Humidity
  • Non-hygroscopic for standard use
  • Mounting Type
  • Sample holder in compatible spectrophotometer/fluorimeter
  • Max Height
  • Approx. 45 mm (standard cuvette design)
  • Test Range
  • 190 nm - 900 nm (material dependent, e.g., quartz, glass)
  • Automation Grade
  • Manual
  • Number of Specimens
  • Single or Multiple (Depends on usage)
  • Application
  • Laboratory
  • Hardness
  • High (depends on material, e.g., quartz hardness Mohs ~7)
  • Material
  • Glass
  • Port Size
  • 12.5 mm x 12.5 mm (standard OD for spectrophotometer cuvettes)
  • Features
  • Optically clear; acid/alkali resistant; reusable (quartz/glass type); standard and micro variations
  • Usage
  • Laboratory analytical testing
  • Control Mode
  • Manual use
  • Path Length
  • 10 mm (standard), other sizes on request
  • Lid Type
  • With or without PTFE cap (optional)
  • Material
  • Optical Glass/Borosilicate/Quartz (as required)
  • Equipment Type
  • Cuvette for Spectrophotometer and Fluorimeter
  • Transparency
  • >80% at visible wavelength for quartz/glass
  • Type
  • Standard, Semi-Micro, Micro, Flow-through (available variants)
  • Wavelength Compatibility
  • UV, Visible, NIR range
  • Cleaning Method
  • Washable and autoclavable (for quartz/glass)
  • Chemical Resistance
  • High (especially in Quartz cuvettes)
  • Optical Surfaces
  • 2 sides optically polished (clear sides); 2 sides frosted for handling
 

Cuvette For Spectophotometer And Florimeter Trade Information

  • Minimum Order Quantity
  • 1 Pair
  • Supply Ability
  • 1000 Pairs Per Month
  • Delivery Time
  • 7-10 Days
 

About Cuvette For Spectophotometer And Florimeter

Leveraging on our rich industrial experience we are able to offer Cuvette For Spectrophotometer And Fluorometer. This is designed to hold samples for spectroscopic measurement. Clients can avail the offered Cuvette For Spectrophotometer And Fluorometer from us in various specifications within promised time frame as per their necessities. This is generally made from glass, plastic, or optical-grade quartz. This is perfect for use in front-face illumination experiments.



Precision Optical Performance

Engineered for superior light transmission, our cuvettes offer transmission accuracy over 80% at visible wavelengths. The optically polished surfaces ensure minimal light scatter, enabling precise quantitative and qualitative measurements for spectrophotometric and fluorimetric applications in varied laboratory settings.


Versatile and Durable Design

With various configurations-standard, semi-micro, micro, and flow-through-these cuvettes serve diverse analytical needs. Manufactured from robust glass or quartz, they exhibit excellent resistance to acids and alkalis, withstand repeated washing and autoclaving, and offer long-term reusability without compromising clarity.


Flexible Laboratory Compatibility

Designed for compatibility with most mainstream spectrophotometers and fluorimeters, these cuvettes fit standard OD holders, allowing easy manual insertion and removal. Their adaptable nature makes them suitable for use in research, teaching, and industrial analytical laboratories throughout India.

FAQ's of Cuvette For Spectophotometer And Florimeter:


Q: How should I clean and maintain these cuvettes for spectrophotometry and fluorimetry?

A: The glass and quartz cuvettes are easily washable with common laboratory cleaning solutions and can be autoclaved for sterilization. For best results, handle only by the frosted sides to prevent fingerprints on the optically polished surfaces.

Q: What are the available types and sizes of the cuvettes, and how do they differ?

A: We provide standard, semi-micro, micro, and flow-through cuvettes with a typical path length of 10 mm (standard), though other sizes can be requested. The variants differ in sample volume and flow setup to suit specific analytical requirements.

Q: Where can these cuvettes be used effectively?

A: These cuvettes are intended for laboratory applications, especially in research, educational, and industrial labs across India where spectrophotometric or fluorimetric analysis is performed.

Q: What is the typical process for using these cuvettes in a spectrophotometer or fluorimeter?

A: Fill the cuvette with your sample, ensuring the clear, optically polished sides align with the instrument light path. Insert manually into the sample holder, perform your measurement, and carefully remove after testing.

Q: What benefits do optically polished surfaces and high chemical resistance provide?

A: Optically polished surfaces ensure accurate light transmission and minimize reading errors, while high chemical resistance allows use with a wide range of solvents and reagents, enhancing durability and reusability.

Q: When should a flow-through cuvette variant be selected over standard types?

A: Flow-through cuvettes are best for processes requiring continuous sample movement or automated sampling, while standard types suffice for static, batch testing.

Q: Are these cuvettes compatible with UV and NIR measurements, and what wavelength range do they support?

A: Yes, depending on the material (glass or quartz), the cuvettes are suitable for UV, visible, and NIR applications with a measuring range from 190 nm to 900 nm.

Tell us about your requirement